For media compatibility, select from:
Polycarbonate body (ClearView H20) or
Polysulphone body (ClearView+)
UNRESTRICTED MOUNTING
Allows for horizontal, vertical or inverted installation of the
meter.
COMPACT AND RUGGED DESIGN
Measures less than 8-1/4" long and 2-7/16" diameter with
a rigid tube and union nut design.
VISUAL INSPECTION OF FLUID
The transparent body allows for visual inspection of fluid
conditions. Diagnose problems at a glance.
MULTIPLE MATERIALS AND CALIBRATIONS AVAILABLE
With a variety of wetted materials of
construction and media calibrations, the ClearView™ will be well suited to your
process.
SENSING METHOD ASSURES ACCURACY
The proven variable-area piston metering assembly provides accurate, dependable flow rate
indication.
SUPERIOR READABILITY
High contrast scale/indicator provides easy-to-read flow rate measuring
resolution along with dual units of GPM and LPM.
MULTIPLE PORTING OPTIONS
ClearView end ports are available in a variety of materials, sizes, and threading options, to simplify installation.
LOW COST PRECISION
Measuring accuracy of ±5% of range and repeatability of ±1%.
ENGINEERING SPECIFICATION
The Basic Series Liquid Flow Rate Meter Shall:
- Use the variable area piston metering method to measure flow rate.
- Not require inlet or outlet straight plumbing, or require vertical pipe mounting.
- Have a measuring accuracy of ±5% of full scale with ±1% repeatability.
- Be Lake Monitors No. CV - _ _ - _ _
| Materials of Construction (Wetted Components) |
| |
ClearView H2O |
ClearView + |
|
Brass |
Brass |
|
Polysulphone |
Polysulphone |
Seals |
Buna-N |
Buna-N |
Spring |
Stainless Steel |
Stainless Steel |
Body |
Polycarbonate |
Polysulphone |
Indicator |
Polysulphone |
Polysulphone |
| Performance |
Measuring accuracy: |
±5% of full-scale |
Repeatability: |
±1% of full-scale |
Flow measuring range: |
1– 30 GPM (5-110 LPM) |
Turn Down Ratio (All Ranges): |
10:1 |
Maximum operating pressure: |
325 PSIG (22.4 Bar) |
Maximum operating temperature: |
ClearView H2O 200°F (93°C) ClearView+ 250°F (121°C) |
Filtration requirements: |
74 Micron (200 U.S. mesh) minimum |
| Mechanical Size Code |
|
DIM |
1/2" Female NPTF |
3/4" Female NPTF |
1" Female NPTF |
A |
2-7/16" (62mm) |
2-7/16" (62mm) |
2-7/16" (62mm) |
B |
7-9/16" (192mm) |
7-9/16" (192mm) |
7-5/32" (182mm) |
Port Type |
NPTF, BSPP |
NPTF, BSPP |
NPTF, BSPP |
|