Lake Monitors Inc.
Express Shipping

FlowStat ES Plastic Flow Sensor

FlowStat ES / Economy Series

A Flow Sensor That’s Compatible...
With Your Application And Your Budget.

FlowStat ES Plastic Flow Sensorce

FlowStat ES Plastic Flow SensorWhether it’s a unique flow monitoring application, a limited budget or both, the FlowStat ES is a perfect fit. A new addition to Lake’s line of popular FlowStat® Sensors, the ES version features a durable polypropylene body for cost savings and compatibility with a variety of fluids. The ES sensor also offers a flow measuring accuracy of ±2% of full scale, and is capable of handing pressures up to 150 PSIG and temperatures up to 150°F. For additional compatibility, the FlowStat ES Sensor offers 4-20 mA, 0-5 VDC, pulse or relay outputs. And like most of its products, Lake Monitors backs the FlowStat ES/Economy Flow Sensor with a 5-year warranty.


Engineering Specification

Materials of Construction

WETTED COMPONENTS:

Casing:

Glass-Filled Polypropylene

Cover:

Clear Polycarbonate

Seal:

Buna-N (standard)

Turbine:

Acetal copolymer

Bearing:

PEEK

Shaft:

Stainless steel

NON-WETTED:

Encapsulant:

Epoxy

Strain relief:

Nylon

Lock Ring:

Glass-Filled Polypropylenel

Wire insulation:

High temperature PVC


Performance

Measuring accuracy:

±2% of full-scale

Repeatability:

±0.5% of full-scale

Flow Measuring Range:

0.5-15 GPM (2-60 LPM)
With optional low-flow adapter: 0.1-4.0 GPM (0.4-15 LPM)

Pressure differential:

For specific differential information, see graph below.

Turndown Ratio:

10:1

Temperature Range:

20-150°F

Maximum Pressure:

150 PSIG

Standard calibration media:

Tap water @ 70°F Temperature

 

Pressure Differential

pressure differential

 

Electronic Specifications

4-20 mA VERSION:

Power Requirements: 12-35 VDC, loop-powered

Load driving capacity: 1150 Ohms max.

Maximum transmitting distance: Limited only by wire resistance & supply voltage

Response time: 2 seconds to 90% (step change)

Resolution: Infinite

Over-current limit: Self limiting at 35mA

Other protection: Reverse polarity

Standard Interface: 10' pigtail, 22 AWG multi-conductor cable (electrical connector optional)

0-5 VDC VERSION:

Power Requirements: 12-35 VDC

Maximum Current: 25 mA DC

Minimum Load Resistance: 1000 Ohms

Maximum transmission distance: 200 ft. recommended

Resolution: Infinite

Response time: < 5 seconds to 90% (step change)

Standard Interface: 10' pigtail, 22 AWG multi-conductor cable (electrical connector optional)

PULSE OUTPUT VERSION:

Power Requirements: 5-24 VDC

Response Time: < 100 mS

Maximum current: 25 mA DC

Maximum transmission distance: 200 feet recommended

Minimum load resistance: 1000 Ohms

Protection: Short circuit & reverse polarity

Standard Interface: 10' pigtail, 22 AWG multi-conductor cable (electrical connector optional)

RELAY OUTPUT:

Power Requirements: 12-35 VDC

Maximum transmission distance: 200 feet recommended

Switch Contact: Form C, 5A max @120 or 240 VAC

Hysteresis: 5% of set point maximum

Set point repeatability: 1% of full scale

Standard Interface: 10' pigtail, 22 AWG multi-conductor cable (electrical connector optional)


Mechanical
FlowStat ES CAD

 



































©2011 Lake Monitors

8809 Industrial Drive, Franksville, WI  53126
Phone: 262-884-9800 | Toll Free: 800-850-6110
Fax: 262-884-9810

info@lakemonitors.com