FreeFlow“Accurate & Economic Flow Sensor”

Minimally invasive, low cost segmented wedge flow sensor. Used to monitor and control process water.

No Moving Parts

The segmented wedge element provides a simple and reliable restriction for sensing flow as related to pressure differential

Unrestricted Mounting

Allows the designer to install the meter in any orientation – horizontal, vertical or inverted.

Compact and Rugged Design

Measures less than 10" long and 3-1/2" wide, with a flanged mounting base for simple installation.

Multiple Flow Ranges Available

The FreeFlow™ Sensor is offered with several ranges of calibration to accommodate the requirements typical to process water applications.

Multiple Port Sizes Offered

Standard selection of NPT ports reduces the amount of adapters required for installation.

Low-Cost Precision

Measuring accuracy of ±2% of range and repeatability of ±1/2%.

The FreeFlow™ Sensor Shall:

  • Use the segmented wedge differential producer to measure flow rate as related to pressure.
  • Not require inlet or outlet straight plumbing, or require vertical pipe mounting.
  • Have a measuring accuracy of ±2% of full scale with ±1/2% repeatability.
  • Be Lake Monitors No. FF– _ _ _– _ _ _– _ _

Materials of Construction

End Ports PVC
Wedge Element PVC
Pressure Sensor Polyetherimide
Electrical Enclosure Polycarbonate

Performance

Measuring Accuracy:

 ±2% of full-scale

Repeatability: ±1/2% of full-scale
Full Scale Flow Measuring Range: 5-15 GPM (19-57 LPM)
Turn Down Ratio (All Ranges) 8:1
Maximum Operating Pressure: 125 PSIG (8.6 bar)
Maximum Operating Temperature: 170°F (76°C)
Pressure Differential: See graph on right
Standard Calibration Media: Tap Water @ 70° F

Electronic Specifications

Electronic output:

0-5 VDC (Standard) - 0-10 VDC (Optional)

Power Requirements: 12-35 VDC
Maximum Current Consumption: < 50mADC
Minimum load resistance:

1000 Ohms

Maximum transmission distance: < 200 feet
Resolution: Infinite
Response Time: < 500 mS to 90% (step change)
Protection: Short circuit, transient and reverse polarity
Insert drawing

Mechanical Sizing Code

DIM 3/8" Female NPTF 1/2" Female NPTF 3/4" Female NPTF
A 7-3/4" (197mm) 7-3/4" (197mm) 10" (254mm)
B 3-1/2" (89mm) 3-1/2" (89mm) 3-1/2" (89mm)
C 6-13/64" (158 mm) 6-13/64" (158 mm) 6-13/64" (158 mm)
D 2" (51mm) 2" (51mm) 2" (51mm)


©2004 Lake Monitors

8809 Industrial Drive, Franksville, WI  53126
Phone: 262-884-9800 | Toll Free: 800-850-6110
Fax: 262-884-9810

info@lakemonitors.com

Website Design Top Floor Technologies